Repository logo
  • English
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
Repository logo
  • Communities & Collections
  • Research Outputs
  • Projects
  • People
  • Statistics
  • English
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Log In
    or
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Scholalry Output
  3. Publications
  4. CVT Failures and Impact on Synchrophasor based Dynamic Monitoring
 
  • Details
Options

CVT Failures and Impact on Synchrophasor based Dynamic Monitoring

Date Issued
2023-01-01
Author(s)
Singh, Shaily
Yadav, Ravi
DOI
10.1109/CERA59325.2023.10455700
Abstract
Device malfunctions and instrument failures in a power system cause multi-component tripping, prolonged disruptions, and operational irregularities. The high voltage instrument transformers like capacitive voltage transformers (CVTs) are bound to maloperations/failures due to switching transient over-voltages, bushing failure, filter malfunctions, saturation of intermediate voltage transformer, etc. Among these failures, the transient over-voltages induce a ferro-resonance phenomenon in the CVTs, which could impact the phasor measurement accuracy at the synchrophasors. This paper presents a detailed sensitivity analysis of the frequency response of CVT with model parameter changes and discusses the impact of filter failures on the phasor measured at the synchrophasor. The analysis provides a detailed study of CVT frequency response and ferro-resonance phenomenon with a brief impact analysis on phasor measurement and associated applications. The propositions are tested with simulated detailed CVT models in Matlab/Simulink, where we observed predominant oscillatory dynamics in phasor measurements similar to sub-synchronous resonance making distinction and detection challenging.
Subjects
  • Capacitive voltage tr...

  • ferro resonance

  • frequency response

  • phasor estimation

  • sensitivity analysis